Water Sprinkler Foam Sprinkler for Fire Fiighting
US$1.00 - 5.00 | 60 Pieces (MOQ) |
Production Capacity:
10000000 Piece/Pieces Per Month
Transport Package:
Carton
Payment Terms:
L/C, T/T, Money Gram, Western Union
Quanzhou YLJ Fire-Fighting Equipment Co., Ltd.
Fujian, China
Last Login Date:
May 26, 2016
Business Type:
Trading Company
Main Products:
Fire Hose, Fire Monitor, Foam Bladder Tank, Fire Fighting Water Monitor, Fire Sprinkler, Intelligent Home Device for Fire-Protection, Foam Fire Hydrant, Wet Alarm Valve, Preaction Alarm Valve, Fire Pump Connector
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
PTW
Sprinkler Installation
Ordinary
Sprinkler Head Type
Open
Alarm Valve Type
Wet Alarm Valve
Automatically Opened and Closed Repeatedly
Can Automatically Opened and Closed
Open Fire Sprinkler System Type
Water Spray System
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Dry Alarm Valve Type
Enclosed Type
Alarm Valve Diameter
50mm
Nozzle Flow Coefficient
115
Deluge Valve Type
Piston Type
Size
1/2′′ & 3/4′′&1′′
Trademark
Baian
Specification
Certificated: ISO WSF CCC
Origin
Fujian, China (Mainland)
Product Description
Brief Information of Foam Sprinkler
Low expansion foam means foam mixture after inhalation of air, less than 20 times the volume expansion foam. Crane trestle low expansion foam fire extinguishing system is mainly used for fighting fires of crude oil, gasoline, kerosene, diesel, methanol, acetone, etc. Class B, suitable for oil refineries, chemical plants, oil fields, oil depots, railway tank car unloading oil jetty , hangars and airports. General civil foam fire systems often use low expansion foam fire protection systems. Low expansion foam liquid ordinary protein foam liquid, liquid fluoride protein foam, AFFF solution (light-water foam liquid), a film F protein foam liquid and liquid-resistant foam and other types.
Because of the water-soluble flammable liquids such as ethanol, methanol, acetone, acetic acid acetate and other polar molecules, the general extinguishing foam has damaging effects, general foam extinguishing agent can not be acted upon, should be resistant foam extinguishing agent. Resistant foam extinguishing agent for water-soluble flammable and combustible liquids have good stability, can resist water soluble combustible, flammable liquid damage, fire fighting role to play. Fight not flowing combustible liquids or gases with low expansion foam fire extinguishing system. In addition, it should not be used in conjunction with water guns and spray systems.
The foam sprinkler is a special fire extinguishing parts mainly used in low-expansion foam sprying system which can produce and jet air bubble. When the mixture foam liquid through the pipline to foam sprinkler, the the foam sprinkler outlet will inhalation air to formation air foam, spray on the protection area to extinguishing fire.
Technical Parameters
Size
Working Pressure
MPa
Flow of Mixture Liquid
L/S
Flow Parameter
L/S
Foam Expansion
Times
Installation Height
M
Connecting Thread R
PTW0.9
0.3-0.6
0.9
27
≥6
≥2.5
R1/2''
R3/4''
R1''
PTW1.2
1.2
36
PTW1.5
1.5
45
PTW1.75
1.75
53
Low expansion foam means foam mixture after inhalation of air, less than 20 times the volume expansion foam. Crane trestle low expansion foam fire extinguishing system is mainly used for fighting fires of crude oil, gasoline, kerosene, diesel, methanol, acetone, etc. Class B, suitable for oil refineries, chemical plants, oil fields, oil depots, railway tank car unloading oil jetty , hangars and airports. General civil foam fire systems often use low expansion foam fire protection systems. Low expansion foam liquid ordinary protein foam liquid, liquid fluoride protein foam, AFFF solution (light-water foam liquid), a film F protein foam liquid and liquid-resistant foam and other types.
Because of the water-soluble flammable liquids such as ethanol, methanol, acetone, acetic acid acetate and other polar molecules, the general extinguishing foam has damaging effects, general foam extinguishing agent can not be acted upon, should be resistant foam extinguishing agent. Resistant foam extinguishing agent for water-soluble flammable and combustible liquids have good stability, can resist water soluble combustible, flammable liquid damage, fire fighting role to play. Fight not flowing combustible liquids or gases with low expansion foam fire extinguishing system. In addition, it should not be used in conjunction with water guns and spray systems.
The foam sprinkler is a special fire extinguishing parts mainly used in low-expansion foam sprying system which can produce and jet air bubble. When the mixture foam liquid through the pipline to foam sprinkler, the the foam sprinkler outlet will inhalation air to formation air foam, spray on the protection area to extinguishing fire.
Technical Parameters
Size
Working Pressure
MPa
Flow of Mixture Liquid
L/S
Flow Parameter
L/S
Foam Expansion
Times
Installation Height
M
Connecting Thread R
PTW0.9
0.3-0.6
0.9
27
≥6
≥2.5
R1/2''
R3/4''
R1''
PTW1.2
1.2
36
PTW1.5
1.5
45
PTW1.75
1.75
53